AZoBuild - The A to Z of Building
 



 


"Air flow" Search Results


Your Search returned these results: page: « 1 2 3 4 5 »

Perimeter chilled beams
09-Jul-04
Advice is given on the design and operation of chilled beam cooling systems so as to maximise their effectiveness. Topic.

Dynamic insulation for energy saving and comfort
09-Jul-04
Air enters a dynamic insulation system through a permeable insulating layer, such that heat which would have been lost by conduction is recovered by the incoming air. Topic.

Measurement and simulation of indoor air quality and energy consumption in two Shanghai office ...
04-Jun-04
Two modern office buildings in Shanghai with typical variable air volume ( VAV ) systems were selected. Technical Brief.

Performance of porous ceramic evaporators for building cooling application
04-Jun-04
The use of porous ceramic evaporators for air conditioning was studied. Technical Brief.

Application of CFD in retrofitting air-conditioning systems in industrial buildings
04-Jun-04
A practical case study was made using computational fluid dynamics ( CFD ) in retrofitting the large cabinet fans and airflow channels in malt processing air-conditioning systems in order to get uniform airflow field, to increase fan capacity and reduce energy consumption. Technical Brief.

Experiments on the ventilation efficiency of turbine ventilators used for building and factory ...
04-Jun-04
Turbine ventilators use natural wind force to rotate the turbine and create a negative pressure at the down-stream end of the pipeline to exhaust airflow. Technical Brief.

Control design of open-cycle desiccant cooling systems using a graphical environment tool
26-Mar-04
Control strategies for open-cycle desiccant cooling systems were developed using SIMBAD ( simulator of buildings and devices ) with the addition of specific HVAC component models running in the Matlab/Simulink environment. Technical Brief.

Advanced HVAC modelling with FemLab / Simulink / MatLab
26-Mar-04
The MatLab toolboxes FemLab and Simulink were evaluated for solving HVAC problems by the solution of partial differential equations. Technical Brief.

Application of fuzzy control in naturally ventilated buildings for summer conditions
19-Mar-04
The process of designing a supervisory control to provide thermal comfort and adequate air distribution inside a single-sided naturally ventilated test room is described. Technical Brief.

Non-dimensional groups for air solar collectors
19-Mar-04
The radiant heat captured by a passive air solar collector during a day divides itself into three fractions, of which one is transmitted by conduction to the backside, one is collected by the convective air flow, and one is lost through glazing. Technical Brief.

page: « 1 2 3 4 5 »

top

 

AZoBuild - The A to Z of Building Technology...AZoM™.com Pty.Ltd Copyright © 2000-2010