Weighs of Celcon Blocks and Blockwork - Normal Format Blocks

Not all Thicknesses shown below are available in each block range

Thickness Ranging from 75-200 (mm)

Thickness (mm)

75

90

100

115

125

130

135

140

150

190

200

No.of blocks per Clampak

130

110

100

90

80

80

80

70

70

50

50

Weight Per Clampack (Kg)

Weight per Clampak (Kg)

Super Solar

461

468

473

490

473

492

511

464

497

449

473

Solar

536

544

550

569

550

572

594

539

577

522

550

Standard

755

767

775

802

775

806

837

759

814

736

775

Hi-Seven/Hi-Tene

816

829

837

867

837

871

904

820

879

795

837

No. Of Blocks Per 1000 (Kg)

No. of blocks per 1000(Kg)

Super Solar

282

235

211

184

169

163

157

151

141

111

106

Solar

243

202

182

158

146

140

135

130

121

96

91

Standard

172

143

129

112

103

99

96

92

86

68

65

Hi-Seven/Hi-Tene

159

133

119

104

96

92

88

85

80

63

60

Typical Block Handling Weights (kg)

Typical block handling weights (Kg) at typical moisture content when laid. Some manufacturers may quote weights which do not include this allowance.

Super Solar

3.5

4.3

4.7

5.4

5.9

6.1

6.4

6.6

7.1

9.0

9.5

Solar

4.1

4.9

5.5

6.3

6.9

7.1

7.4

7.7

8.2

10.4

11.0

Standard

5.8

7.0

7.7

8.9

9.7

10.1

10.5

10.8

11.6

14.7

15.5

Hi-Seven/Hi-Tene

6.3

7.5

8.4

9.6

10.5

10.9

11.3

11.7

12.6

15.9

16.7

Laid Weight of Blocks Including 10mm Mortar Joints, Excluding Finishes (Kg/m2)

Laid weight of blocks including 10mm mortar joints, excluding finishes (Kg/m2)

Super Solar

40

48

53

61

66

69

71

74

79

101

106

Solar

43

51

57

65

71

74

77

79

85

108

114

Standard

54

65

72

83

90

94

97

101

108

137

144

Hi-Seven/Hi-Tene

64

76

85

97

106

110

114

120

127

161

169

Thickness Ranging from 215-355 (mm)

Thickness (mm)

215

225

230

250

255

260

265

275

280

300

355

No. of blocks per Clampak

50

50

40

40

40

40

40

40

40

30

30

Weight Per Clampack (Kg)

Weight per Clampak (Kg)

Super Solar

508

532

435

473

482

492

501

520

530

426

504

Solar

591

618

506

550

561

572

583

605

616

495

585

Standard

833

872

713

775

790

806

821

852

868

697

825

Hi-Seven/Hi-Tene

900

942

770

837

854

871

887

921

938

753

892

No. Of Blocks Per 1000 (Kg)

No. of blocks per 1000(Kg)

Super Solar

98

94

92

85

83

81

80

77

76

70

60

Solar

85

81

79

73

71

70

69

66

65

61

51

Standard

60

57

56

52

51

50

49

47

46

43

36

Hi-Seven/Hi-Tene

56

53

52

48

47

46

45

43

43

40

34

Typical Block Handling Weights (kg)

Typical block handling weights (Kg) at typical moisture content when laid. Some manufacturers may quote weights which do not include this allowance.

Super Solar

10.2

10.6

10.9

11.8

12.1

12.3

12.5

13.0

13.2

14.2

16.8

Solar

11.8

12.4

12.6

13.7

14.0

14.3

14.6

15.1

15.4

16.5

19.5

Standard

16.7

17.4

17.8

19.4

19.8

20.1

20.5

21.3

21.7

23.2

27.5

Hi-Seven/Hi-Tene

18.0

18.8

19.3

20.9

21.3

21.8

22.2

23.0

23.4

25.1

29.7

Laid Weight of Blocks Including 10mm Mortar Joints, Excluding Finishes (Kg/m2)

Laid weight of blocks including 10mm mortar joints, excluding finishes (Kg/m2)

Super Solar

114

119

122

132

135

138

140

146

148

159

188

Solar

122

128

131

142

145

148

150

156

159

170

202

Standard

155

162

166

180

184

188

191

198

202

216

256

Hi-Seven/Hi-Tene

182

191

195

212

216

220

224

233

237

254

301

FOUNDATION BLOCKS

- above data for the equivalent block applies: eg for Foundation 4 see Standard; for Foundation 7 see Hi-Seven, etc

For PLUS format blocks (610mm long x 140mm high)

For JUMBO PLUS format blocks (610mm long x 270mm high)

NORMAL Format Blocks (440mm long x 215mm high; 9.88 blocks/m2 laid)

This information has been sourced, reviewed and adapted from materials provided by H + H Celcon.

For more information on this source, please visit H + H Celcon.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    H + H Celcon. (2019, April 23). Weighs of Celcon Blocks and Blockwork - Normal Format Blocks. AZoBuild. Retrieved on April 19, 2024 from https://www.azobuild.com/article.aspx?ArticleID=7926.

  • MLA

    H + H Celcon. "Weighs of Celcon Blocks and Blockwork - Normal Format Blocks". AZoBuild. 19 April 2024. <https://www.azobuild.com/article.aspx?ArticleID=7926>.

  • Chicago

    H + H Celcon. "Weighs of Celcon Blocks and Blockwork - Normal Format Blocks". AZoBuild. https://www.azobuild.com/article.aspx?ArticleID=7926. (accessed April 19, 2024).

  • Harvard

    H + H Celcon. 2019. Weighs of Celcon Blocks and Blockwork - Normal Format Blocks. AZoBuild, viewed 19 April 2024, https://www.azobuild.com/article.aspx?ArticleID=7926.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.