Mechanical characteristics of virgin and strengthened old brick masonry - experimental research

Summary

The mechanical characteristics of virgin and strengthened old masonry were experimentally determined.  Samples of old brick masonry, constructed in 1906 in the city of Thessaloniki, were taken and examined.  Specimens of the bricks and mortar were tested in compression and tension.  Then several specimens of virgin masonry were formed and tested in compression (type C specimens), in combined direct  shear in joints and compression (type S wallettes) and in combined diagonal and axial compression (type D specimens). Afterwards, another group of type C and D specimens was coated by unilateral or bilateral thin reinforced mortar jacket and tested under the same loading as in the case of the corresponding virgin ones.  It was concluded that, as expected, the constituent materials are rather poor, reveal high scatter and result in a relatively low compressive strength of the virgin masonry; the strengthening technique used does not increase the compressive strength of the masonry; that increasing the compression in bed joints increases the local shear strength in joints; that the same "friction" effect is also obvious in specimens tested in combined diagonal and axial compression; and that the strengthening technique used considerably increases the shear strength of the masonry.  13 refs.

Primary author(s): Kosmas S; Christos I

                            Thessaloniki,Aristotle University

Source: Masonry Int.

            16,No.2,2003,p.62-69