Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m

Inner Leaf: With 10mm Joints

Solar

JumboPlus

Normal/Plus

Internal Finish

100 (mm)

115 (mm)

125 (mm)

100 (mm)

115 (mm)

125

(mm)

150 (mm)

200 (mm)

40mm ThermaLine Plus

0.40

0.38

0.37

0.41

0.39

0.38

0.35

0.32

60mm Thermaline PLATINUM

0.33

0.32

0.31

0.34

0.32

0.32

0.30

0.27

50mm ThermaLine SUPER

0.31

0.30

0.39

0.31

0.30

0.30

0.28

0.26

65mm ThermaLine SUPER

0.25

0.24

0.24

0.25

0.25

0.24

0.23

0.21

U-Values for Clear Cavity Walls Using Celcon Standard Aircrete Blocks

Inner Leaf: With 10mm Joints

Standard

JumboPlus

Normal/Plus

Internal Finish

100 (mm)

115 (mm)

100 (mm)

115 (mm)

125 (mm)

150 (mm)

40mm ThermaLine Plus

0.43

0.41

0.44

0.42

0.41

0.39

60mm Thermaline PLATINUM

0.36

0.34

0.36

0.35

0.34

0.32

50mm ThermaLine SUPER

0.33

0.32

0.33

0.32

0.32

0.30

65mm ThermaLine SUPER

0.26

0.26

0.27

0.26

0.26

0.25

U-Values for Clear Cavity Walls Using Celcon Hi-Strength Aircrete Blocks

Inner Leaf: With 10mm Joints

Hi-Strength

JumboPlus

Normal/Plus

Internal Finish

100

(mm)

100

(mm)

125

(mm)

190

(mm)

40mm ThermaLine Plus

0.46

0.46

0.44

0.39

60mm Thermaline PLATINUM

0.37

0.37

0.38

0.32

50mm ThermaLine SUPER

0.34

0.34

0.33

0.30

65mm ThermaLine SUPER

0.27

0.27

0.26

0.25

Block format:
Normal: 440mm long x 215mm high
Plus: 610mm long x 215mm high
JumboPlus: 610mm long x 270mm high

440 x 215 x 100mm blocks with 10mm joints

This information has been sourced, reviewed and adapted from materials provided by H + H Celcon.

For more information on this source, please visit H + H Celcon.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    H + H Celcon. (2019, April 23). Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m. AZoBuild. Retrieved on June 01, 2023 from https://www.azobuild.com/article.aspx?ArticleID=7892.

  • MLA

    H + H Celcon. "Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m". AZoBuild. 01 June 2023. <https://www.azobuild.com/article.aspx?ArticleID=7892>.

  • Chicago

    H + H Celcon. "Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m". AZoBuild. https://www.azobuild.com/article.aspx?ArticleID=7892. (accessed June 01, 2023).

  • Harvard

    H + H Celcon. 2019. Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m. AZoBuild, viewed 01 June 2023, https://www.azobuild.com/article.aspx?ArticleID=7892.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit