Coursing Units from H+H Celcon – Enables Builders to Comply with Building Regulations

H+H Celcon’s Coursing Units are produced from the same material as conventional size Celcon blocks. They have a face size of 215mm x 65mm and are available in thicknesses from 100mm to 150mm, match our product range.

When used with conventional size Celcon blocks, Coursing Units enable builders to comply with Building Regulations simply by ensuring a consistency in materials within the building fabric, reducing thermal bridging. (Storey height (2.4m) when built with traditional mortar is ten courses of 215mm blocks and two of coursing units).

They are suitable for all the same applications as conventional size blocks reducing costs by saving time on site, significantly reducing the need for cutting and thus site wastage.

They are suitable for use both externally and internally in loadbearing* and non-loadbearing situations above and below dpc.

*Walls should not be constructed with Coursing Units as the sole masonry unit. For loadbearing walls, the location of Coursing Units should be confirmed with the designer.

Benefits

  • Saving time on site cutting blocks
  • Reducing site wastage
  • Avoid thermal bridging – allowing consistency within the building fabric
  • Allow compliance with the Building Regulations

Applications

  • Infill above doors and windows
  • Coursing at floor and ceiling levels
  • Cavity closing at reveals and eaves
  • Making up between joists and beam and block floors
  • Usable with traditional and thin layer masonry

Technical Specification

Coursing Units – 215 x 65mm face size

Unit Thickness (mm) = T

100

115

125

140

150

Coursing UnitWeight at 3% (kg)†

0.84

0.96

1.05

1.17

1.26

Coursing UnitWeight (kg)††

1.08

1.24

1.35

1.51

1.62

Coursing PackWeight (kg)**

323

372

404

453

485

Hi-7 Coursing Unit Weight at 3% (kg)†

1.05

1.21

1.31

1.47

1.57

Hi-7 Coursing Unit Weight (kg)††

1.24

1.42

1.55

1.73

1.86

Hi-7 Coursing PackWeight (kg) **

371

427

464

519

557

Hi-10e Coursing Unit Weight at 3% (kg)†

1.05

1.21

1.31

1.47

1.57

Hi-10e Coursing Unit Weight (kg)††

1.24

1.42

1.55

1.73

1.86

Hi-10e Coursing PackWeight (kg) **

371

427

464

519

557

Coursing Units – 215 x 65mm face size

Coverage per pack (m2) – 10mm joint

5.0

5.0

5.0

5.0

5.0

Coverage per pack (m2) – 2mm joint

4.3

4.3

4.3

4.3

4.3

Number of units per pack

300

300

300

300

300

Pack height (mm) = H

400

460

500

560

600

Coursing Unit

Hi-7 Coursing Unit

Hi-10e Coursing Unit

Compressive Strength

2.9N/mm2*

7.3N/mm2*

8.7N/mm2*•

Thermal Conductivity

0.15 W/mK

0.19 W/mK

0.19 W/mK

Density

460 kg/m3

750 kg/m3

750 kg/m3

* Compressive strengths quoted are to the European Standard BS EN 771-4.

** Pack weight excludes pallet. † Unit weights calculated at 3% moisture content by weight.

†† Unit weights at typical moisture content when laid. (Some manufacturers may quote weights which have not allowed for this.)

• Hi-10e is equivalent to 10.4N/mm2

20.4 Bold figures indicate that the product is above single person repetitive manual handling limits.
All shaded areas indicate that the product is a stock item at all factories.

This information has been sourced, reviewed and adapted from materials provided by H + H Celcon.

For more information on this source, please visit H + H Celcon.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    H + H Celcon. (2019, April 23). Coursing Units from H+H Celcon – Enables Builders to Comply with Building Regulations. AZoBuild. Retrieved on October 11, 2024 from https://www.azobuild.com/article.aspx?ArticleID=7877.

  • MLA

    H + H Celcon. "Coursing Units from H+H Celcon – Enables Builders to Comply with Building Regulations". AZoBuild. 11 October 2024. <https://www.azobuild.com/article.aspx?ArticleID=7877>.

  • Chicago

    H + H Celcon. "Coursing Units from H+H Celcon – Enables Builders to Comply with Building Regulations". AZoBuild. https://www.azobuild.com/article.aspx?ArticleID=7877. (accessed October 11, 2024).

  • Harvard

    H + H Celcon. 2019. Coursing Units from H+H Celcon – Enables Builders to Comply with Building Regulations. AZoBuild, viewed 11 October 2024, https://www.azobuild.com/article.aspx?ArticleID=7877.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.