Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks

Inner Leaf: With 10mm Joints

Solar

Standard

Hi-Strength

JumboPlus

Normal/Plus

JumboPlus

Normal/Plus

Jumbo Plus

Normal/Plus

Internal Finish

100
(mm)

115 (mm)

125 (mm)

100 (mm)

115 (mm)

150 (mm)

200 (mm)

100 (mm)

115 (mm)

100 (mm)

125 (mm)

150 (mm)

190 (mm)

100 (mm)

100 (mm)

125 (mm)

190 (mm)

40mm ThermaLine Plus

0.41

0.39

0.38

0.42

0.40

0.36

0.32

0.45

0.43

0.45

0.42

0.40

0.37

0.47

0.47

0.45

0.40

60mm Thermaline PLATINUM

0.34

0.33

0.32

0.34

0.33

0.31

0.28

0.36

0.35

0.37

0.35

0.33

0.31

0.38

0.38

0.36

0.33

50mm ThermaLine SUPER

0.32

0.31

0.30

0.32

0.31

0.29

0.26

0.34

0.33

0.34

0.32

0.31

0.29

0.35

0.35

0.34

0.31

65mm ThermaLine SUPER

0.26

0.25

0.24

0.26

0.25

0.24

0.22

0.27

0.26

0.27

0.26

0.25

0.24

0.28

0.28

0.27

0.25

Block format:                                                                                
Normal: 440mm long x 215mm high
Plus: 610mm long x 215mm high
JumboPlus: 610mm long x 270mm high

Brickwork:
215 x 65 x 102.5 bricks with 10mm joints

This information has been sourced, reviewed and adapted from materials provided by H + H Celcon.

For more information on this source, please visit H + H Celcon.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    H + H Celcon. (2019, April 23). Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks. AZoBuild. Retrieved on August 17, 2019 from https://www.azobuild.com/article.aspx?ArticleID=7890.

  • MLA

    H + H Celcon. "Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks". AZoBuild. 17 August 2019. <https://www.azobuild.com/article.aspx?ArticleID=7890>.

  • Chicago

    H + H Celcon. "Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks". AZoBuild. https://www.azobuild.com/article.aspx?ArticleID=7890. (accessed August 17, 2019).

  • Harvard

    H + H Celcon. 2019. Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks. AZoBuild, viewed 17 August 2019, https://www.azobuild.com/article.aspx?ArticleID=7890.

Ask A Question

Do you have a question you'd like to ask regarding this article?

Leave your feedback
Submit