Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks

Inner Leaf: With 10mm Joints

Solar

Standard

Hi-Strength

JumboPlus

Normal/Plus

JumboPlus

Normal/Plus

Jumbo Plus

Normal/Plus

Internal Finish

100
(mm)

115 (mm)

125 (mm)

100 (mm)

115 (mm)

150 (mm)

200 (mm)

100 (mm)

115 (mm)

100 (mm)

125 (mm)

150 (mm)

190 (mm)

100 (mm)

100 (mm)

125 (mm)

190 (mm)

40mm ThermaLine Plus

0.41

0.39

0.38

0.42

0.40

0.36

0.32

0.45

0.43

0.45

0.42

0.40

0.37

0.47

0.47

0.45

0.40

60mm Thermaline PLATINUM

0.34

0.33

0.32

0.34

0.33

0.31

0.28

0.36

0.35

0.37

0.35

0.33

0.31

0.38

0.38

0.36

0.33

50mm ThermaLine SUPER

0.32

0.31

0.30

0.32

0.31

0.29

0.26

0.34

0.33

0.34

0.32

0.31

0.29

0.35

0.35

0.34

0.31

65mm ThermaLine SUPER

0.26

0.25

0.24

0.26

0.25

0.24

0.22

0.27

0.26

0.27

0.26

0.25

0.24

0.28

0.28

0.27

0.25

Block format:                                                                                
Normal: 440mm long x 215mm high
Plus: 610mm long x 215mm high
JumboPlus: 610mm long x 270mm high

Brickwork:
215 x 65 x 102.5 bricks with 10mm joints

This information has been sourced, reviewed and adapted from materials provided by H + H Celcon.

For more information on this source, please visit H + H Celcon.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    H + H Celcon. (2019, April 23). Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks. AZoBuild. Retrieved on April 19, 2024 from https://www.azobuild.com/article.aspx?ArticleID=7890.

  • MLA

    H + H Celcon. "Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks". AZoBuild. 19 April 2024. <https://www.azobuild.com/article.aspx?ArticleID=7890>.

  • Chicago

    H + H Celcon. "Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks". AZoBuild. https://www.azobuild.com/article.aspx?ArticleID=7890. (accessed April 19, 2024).

  • Harvard

    H + H Celcon. 2019. Cavity Walls: U Values (W/m2K) Outer Leaf Brickwork and Inner Leaf Aircrete Blocks. AZoBuild, viewed 19 April 2024, https://www.azobuild.com/article.aspx?ArticleID=7890.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.