Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf Aircrete

AZoBuild, The A to Z of Building Technology - H&H Celcon Logo

U-Values for Clear Cavity Walls Using Celcon Solar Aircrete Blocks

U-Values for Clear Cavity Walls Using Celcon Standard Aircrete Blocks

U-Values for Clear Cavity Walls Using Celcon Hi-Strength Aircrete Blocks

U-Values for Clear Cavity Walls Using Celcon Solar Aircrete Blocks

 

Inner Leaf: With 10mm Joints

 

Solar

 

JumboPlus

Normal/Plus

Internal Finish

100 (mm)

115 (mm)

125 (mm)

100 (mm)

115 (mm)

125

(mm)

150 (mm)

200 (mm)

40mm ThermaLine Plus

0.34

0.33

0.32

0.35

0.34

0.33

0.31

0.28

60mm Thermaline PLATINUM

0.29

0.28

0.28

0.30

0.29

0.28

0.27

0.24

50mm ThermaLine SUPER

0.28

0.27

0.26

0.28

0.27

0.27

0.25

0.23

65mm ThermaLine SUPER

0.23

0.22

0.22

0.23

0.22

0.22

0.20

0.20

U-Values for Clear Cavity Walls Using Celcon Standard Aircrete Blocks

 

Inner Leaf: With 10mm Joints

 

Standard

 

JumboPlus

Normal/Plus

Internal Finish

100

(mm)

115 (mm)

100 (mm)

115 (mm)

125 (mm)

150 (mm)

40mm ThermaLine Plus

 

0.37

 

0.36

 

0.37

 

0.36

 

0.35

 

0.33

60mm Thermaline PLATINUM

 

0.31

 

0.30

 

0.31

 

0.30

 

0.30

 

0.29

50mm ThermaLine SUPER

 

0.29

 

0.28

 

0.29

 

0.29

 

0.28

 

0.27

65mm ThermaLine SUPER

 

0.24

 

0.23

 

0.24

 

0.23

 

0.23

 

0.22

U-Values for Clear Cavity Walls Using Celcon Hi-Strength Aircrete Blocks

 

Inner Leaf: With 10mm Joints

 

Hi-Strength

 

Jumbo Plus

Normal/Plus

Internal Finish

100 (mm)

100
(mm)

115
(mm)

125
(mm)

150
(mm)

40mm ThermaLine Plus

 

0.38

 

0.39

 

0.38

 

0.37

 

0.35

60mm Thermaline PLATINUM

 

0.32

 

0.32

 

0.32

 

0.31

 

 

0.30

50mm ThermaLine SUPER

 

0.30

 

0.30

 

0.30

 

0.29

 

0.28

40mm ThermaLine Plus

 

0.24

 

0.25

 

0.24

 

0.24

 

0.23

Block format:
Normal: 440mm long x 215mm high
Plus: 610mm long x 215mm high
JumboPlus: 610mm long x 270mm high

Block face format as inner leaf x 100mm thick with 10mm joints