Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf Aircrete

Inner Leaf: With 10mm Joints

Solar

JumboPlus

Normal/Plus

Internal Finish

100 (mm)

115 (mm)

125 (mm)

100 (mm)

115 (mm)

125

(mm)

150 (mm)

200 (mm)

40mm ThermaLine Plus

0.34

0.33

0.32

0.35

0.34

0.33

0.31

0.28

60mm Thermaline PLATINUM

0.29

0.28

0.28

0.30

0.29

0.28

0.27

0.24

50mm ThermaLine SUPER

0.28

0.27

0.26

0.28

0.27

0.27

0.25

0.23

65mm ThermaLine SUPER

0.23

0.22

0.22

0.23

0.22

0.22

0.20

0.20

U-Values for Clear Cavity Walls Using Celcon Standard Aircrete Blocks

Inner Leaf: With 10mm Joints

Standard

JumboPlus

Normal/Plus

Internal Finish

100

(mm)

115 (mm)

100 (mm)

115 (mm)

125 (mm)

150 (mm)

40mm ThermaLine Plus

0.37

0.36

0.37

0.36

0.35

0.33

60mm Thermaline PLATINUM

0.31

0.30

0.31

0.30

0.30

0.29

50mm ThermaLine SUPER

0.29

0.28

0.29

0.29

0.28

0.27

65mm ThermaLine SUPER

0.24

0.23

0.24

0.23

0.23

0.22

U-Values for Clear Cavity Walls Using Celcon Hi-Strength Aircrete Blocks

Inner Leaf: With 10mm Joints

Hi-Strength

Jumbo Plus

Normal/Plus

Internal Finish

100 (mm)

100
(mm)

115
(mm)

125
(mm)

150
(mm)

40mm ThermaLine Plus

0.38

0.39

0.38

0.37

0.35

60mm Thermaline PLATINUM

0.32

0.32

0.32

0.31

0.30

50mm ThermaLine SUPER

0.30

0.30

0.30

0.29

0.28

40mm ThermaLine Plus

0.24

0.25

0.24

0.24

0.23

Block format:
Normal: 440mm long x 215mm high
Plus: 610mm long x 215mm high
JumboPlus: 610mm long x 270mm high

Block face format as inner leaf x 100mm thick with 10mm joints

This information has been sourced, reviewed and adapted from materials provided by H + H Celcon.

For more information on this source, please visit H + H Celcon.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    H + H Celcon. (2019, April 23). Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf Aircrete. AZoBuild. Retrieved on August 20, 2019 from https://www.azobuild.com/article.aspx?ArticleID=7893.

  • MLA

    H + H Celcon. "Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf Aircrete". AZoBuild. 20 August 2019. <https://www.azobuild.com/article.aspx?ArticleID=7893>.

  • Chicago

    H + H Celcon. "Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf Aircrete". AZoBuild. https://www.azobuild.com/article.aspx?ArticleID=7893. (accessed August 20, 2019).

  • Harvard

    H + H Celcon. 2019. Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf Aircrete. AZoBuild, viewed 20 August 2019, https://www.azobuild.com/article.aspx?ArticleID=7893.

Ask A Question

Do you have a question you'd like to ask regarding this article?

Leave your feedback
Submit