Cavity Walls: U Values (W/m2k) for Tiles and Timber on Battens Using Outer Leaf Aircrete Blocks

Inner Leaf: With 2mm Celfix Mortar Joints

Solar

Jumbo Plus

Normal/Plus

Tiles on Battens

Cavity

Internal Finish

100 (mm)

100 (mm)

115 (mm)

125 (mm)

150 (mm)

Clear

50mm ThermaLineSUPER

0.26

0.26

0.25

0.25

0.23

Partially Filled 20mm Kingspan TW50

Dense Plaster

0.31

0.32

0.30

0.30

0.28

Fully Fitted 50mm Dritherm

Dense Plaster

0.31

0.31

0.30

0.29

0..27

Timber on Battens

Clear

50mm ThermaLineSUPER

0.24

0.24

0.24

0.23

0.22

Partially Filled 20mm CW3020

Dense Plaster

0.30

0.30

0.29

0.28

0.26

Fully Fitted 50mm IsowoolCWS/Rockwool

Dense Plaster

0.29

0.29

0.28

0.28

0.26

U-Values for Tile and Timber Batten Using Celcon Standard Aircrete Blocks

Inner Leaf: With 2mm Celfix Mortar Joints

Standard

Jumbo Plus

Normal/Plus

Tiles on Battens

Cavity

Internal Finish

100 (mm)

100 (mm)

115 (mm)

125 (mm)

150 (mm)

Clear

50mm ThermaLineSUPER

0.27

0.27

0.27

0.26

0.25

Partially Filled 20mm Kingspan TW50

Dense Plaster

0.34

0.34

0.33

0.32

0.31

Fully Fitted 50mm Dritherm

Dense Plaster

0.33

0.33

0.32

0.31

0.30

Timber on Battens

Clear

50mm ThermaLineSUPER

0.26

0.26

0.25

0.25

0.24

Partially Filled  20mm CW3020

Dense Plaster

0.32

0.32

0.31

0.30

0.29

Fully Fitted 50mm IsowoolCWS/Rockwool

Dense Plaster

0.31

0.31

0.30

0.30

0.29

U-Values for Tile and Timber Battens Using Celcon Hi-Strength Aircrete Blocks

Inner Leaf: With 2mm Celfix Mortar Joints

Hi-Strength

Jumbo Plus

Normal/Plus

Tiles on Battens

Cavity

Internal Finish

100 (mm)

100 (mm)

115 (mm)

125 (mm)

150 (mm)

Clear

50mm ThermaLineSUPER

0.28

0.28

0.28

0.27

0.27

Partially Filled 20mm Kingspan TW50

Dense Plaster

0.35

0.35 lwt plaster

0.35

0.34

0.33

Fully Fitted 50mm Dritherm

Dense Plaster

0.34

0.35

0.33

0.34

0.32

Timber on Battens

Clear

50mm ThermaLineSUPER

0.27

0.27

0.26

0.26

0.25

Partially Filled  20mm CW3020

Dense Plaster

0.33

0.33

0.32

0.32

0.31

Fully Fitted 50mm IsowoolCWS/Rockwool

Dense Plaster

0.33

0.33

0.32

0.31

0.30

Block format:
Normal: 440mm long x 215mm high
Plus: 610mm long x 215mm high
JumboPlus: 610mm long x 270mm high

Block face format as inner leaf x 100mm thick with 2mm joints

This information has been sourced, reviewed and adapted from materials provided by H + H Celcon.

For more information on this source, please visit H + H Celcon.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    H + H Celcon. (2019, April 23). Cavity Walls: U Values (W/m2k) for Tiles and Timber on Battens Using Outer Leaf Aircrete Blocks. AZoBuild. Retrieved on May 28, 2023 from https://www.azobuild.com/article.aspx?ArticleID=7908.

  • MLA

    H + H Celcon. "Cavity Walls: U Values (W/m2k) for Tiles and Timber on Battens Using Outer Leaf Aircrete Blocks". AZoBuild. 28 May 2023. <https://www.azobuild.com/article.aspx?ArticleID=7908>.

  • Chicago

    H + H Celcon. "Cavity Walls: U Values (W/m2k) for Tiles and Timber on Battens Using Outer Leaf Aircrete Blocks". AZoBuild. https://www.azobuild.com/article.aspx?ArticleID=7908. (accessed May 28, 2023).

  • Harvard

    H + H Celcon. 2019. Cavity Walls: U Values (W/m2k) for Tiles and Timber on Battens Using Outer Leaf Aircrete Blocks. AZoBuild, viewed 28 May 2023, https://www.azobuild.com/article.aspx?ArticleID=7908.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit